Customization: | Available |
---|---|
Heading Accuracy: | 0.06 |
Pitch & Roll Accuracy: | 0.005 |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Project
|
|
Indicators
|
Remark
|
|
Gyro channel
|
Measuring range
|
-500°/s ~+500°/s
|
|
|
|
Resolution
|
≤0.01°/h
|
|
|
|
Zero-bias residual
|
-0.02°/h ~+0.02°/h
|
|
|
|
Random walk
|
≤0.0015°/√h
|
|
|
|
Zero bias stability at room temperature
|
≤0.01°/h(1σ,10s)
|
10 seconds smoothing, 1H test result
|
|
|
Zero bias stability at full temperature
|
≤0.015°/h(1σ,10s)
|
10 seconds smoothing, 1H test result
|
|
|
Normal-temperature zero-bias repeatability
|
≤0.01°/h(1σ)
|
Statistics of 6 test data
|
|
|
Zero-bias repeatability at full temperature
|
≤0.015°/h(1σ)
|
Take 2 zero-bias data at full temperature, high temperature, low temperature and normal temperature respectively
|
|
|
Scale factor nonlinearity
|
≤5ppm
|
Full temperature and constant temperature
|
|
|
Scale factor repeatability
|
≤5ppm(1σ)
|
Full temperature and constant temperature
|
|
|
Gyro start time
|
≤5s
|
|
|
|
Gyro bandwidth
|
>300Hz
|
Design assurance, batch testing
|
|
|
Installation error residual of three-axis gyroscope
|
≤10"
|
|
|
Acceleration channel
|
Measuring range
|
-20g ~ +20g
|
Design and selection guarantee
|
|
|
Zero bias stability at full temperature
|
≤50ug(1σ)
|
10 seconds smoothing, 1H test result
|
|
|
Zero-bias repeatability at full temperature
|
≤80ug(1σ)
|
Take 2 zero-bias data at full temperature, high temperature, low temperature and normal temperature respectively
|
|
|
Add up the starting time
|
≤5s
|
|
|
|
Triaxial addition installation error residual
|
≤10"
|
|