Customization: | Available |
---|---|
Self-North-Seeking Heading Accuracy: | 1.5/Cosl |
Vibration: | 20~2000Hz |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Project
|
|
Indicators
|
Remark
|
|
Gyro |
Measuring range
|
-300°/s ~+300°/s
|
|
|
|
Resolution
|
≤0.5°/h
|
|
|
|
Bias residual
|
-1.0°/h ~+1.0°/h
|
|
|
|
Random walk
|
0.05 o / h
|
|
|
|
Bias stability at room temperature
|
≤0.3°/h(1σ)
|
10 seconds smoothing, 1h test result
|
|
|
Bias stability at full temperature
|
≤0.5°/h(1σ)
|
10 seconds smoothing, 1h test result
|
|
|
Normal-temperature Bias repeatability
|
≤0.3°/h(1σ)
|
Statistics of 6 test data
|
|
|
Bias repeatability at full temperature
|
≤0.5°/h(1σ)
|
Take 2 Biasdata at full temperature, high temperature, low temperature and normal temperature respectively
|
|
|
Scale factor nonlinearity
|
≤200ppm
|
Full temperature and constant temperature
|
|
|
Scale factor repeatability
|
≤200ppm(1σ)
|
Full temperature and constant temperature
|
|
|
Gyro start time
|
≤5s
|
|
|
|
Gyro bandwidth
|
300Hz
|
Design assurance, batch testing
|
|
|
Installation error residual of three-axis gyroscope
|
≤30"
|
|
Project
|
|
Indicators
|
Remark
|
|
Acceleration |
Measuring range
|
-50g ~ +50g
|
Design and selection guarantee
|
|
|
Scale factor nonlinearity
|
≤200ppm
|
Design and selection guarantee
|
|
|
Bias stability at full temperature
|
≤100ug(1σ)
|
10 seconds smoothing, 1H test result
|
|
|
Bias repeatability at full temperature
|
≤100ug(1σ)
|
Take 2 Biasdata at full temperature, high temperature, low temperature and normal temperature respectively
|
|
|
Scale factor repeatability
|
≤100ppm(1σ)
|
Design and selection guarantee
|
|
|
Random walk
|
≤0.02m/s/h1/2
|
|
|
|
Add up the starting time
|
≤5s
|
|
|
|
Triaxial addition installation error residual
|
≤30"
|
|
Project
|
|
Indicators
|
Remark
|
|
Alignment accuracy |
North seeking time
|
≤5min
|
Generally, the standard is 3min or 5min.
|
|
|
Heading Angle Alignment Repeatability
|
≤1°/cosL
|
1σ
|
|
|
Pitch Alignment Repeatability
|
≤0.05°
|
1σ
|
|
|
Roll Angle Alignment Repeatability
|
≤0.05°
|
1σ
|
|
|
|
Optional
|
It can realize swaying base alignment, GPS auxiliary alignment during travel, odometer auxiliary alignment during travel and main
inertial navigation transfer alignment. |
Project
|
|
Indicators
|
Remark
|
|
Alignment accuracy |
North seeking time
|
≤5min
|
Generally, the standard is 3min or 5min.
|
|
|
Heading Angle Alignment Repeatability
|
≤1°/cosL
|
1σ
|
|
|
Pitch Alignment Repeatability
|
≤0.05°
|
1σ
|
|
|
Roll Angle Alignment Repeatability
|
≤0.05°
|
1σ
|
|
|
North-seeking mode
|
Optional
|
It can realize swaying base alignment, GPS auxiliary alignment during travel, odometer auxiliary alignment during travel and main
inertial navigation transfer alignment. |
Project
|
|
Indicators
|
Remark
|
|
Inertial navigation accuracy |
Accuracy of course angle maintenance
|
≤2°/h
|
|
|
|
Pitch Angle Holding Accuracy
|
≤0.2°/h
|
|
|
|
Accuracy of roll angle maintenance
|
≤0.2°/h
|
|
|
|
|
|
|
|
|
Position positioning accuracy of odometer integrated navigation
|
≤ 0.2% (mileage greater than 3 km)
|
|
|
|
Position positioning accuracy of odometer integrated navigation
|
≤1m(50s)
|
|